b
The annex to this document includes a checklist for review by the manufacturer
and installer. Use this checklist as a reference before commissioning the system
for the first time.
b
Document in a clear manner the settings for the safety laser scanner, and the
results of the testing during initial commissioning. For this purpose also print out
the complete configuration of the safety laser scanner (including protective field
shapes) and include these with the documentation.
NOTE
•
Use the
Create diagnostic dump...
function in the CDS (right click on the COM inter‐
face to which the safety laser scanner is connected). You can keep these data as a
backup and in this way document the state during initial commissioning at any
time.
•
Your SICK representative will be pleased to provide you with advice on initial com‐
missioning.
Further topics
•
"Checklist for initial commissioning and commissioning", page 133
8.4
Recommissioning
Overview
If the device has already been put into operation but has been replaced or exchanged
since then, the device automatically reads the saved configuration from the system
plug remaining on the machine.
No acceptance by qualified safety personnel is required after the configuration is read
from the system plug. The check as per the requirements for daily checking must, how‐
ever, be carried out.
7-segment display and LEDs after the power up sequence
Table 19: 7segment display during and after the power up sequence during recommissioning
Step
Display
Meaning
1
,
,
,
,
,
,
,
Power-up cycle, test of the 7-segment display. All segments
are activated consecutively.
2
Saved configuration invalid: Devices in the configuration
mode, no further steps taken
3
Device in dual field mode
Device in triple field mode
4
Waiting for valid inputs
5
Waiting for Reset
6
No display
Device is ready for operation
Device ready for operation but object in the protective field (in
triple field mode)
,
Device ready for operation but object in the first or second
warning field (in triple field mode)
,
Device ready for operation but object in the protective field or
in the simultaneous protective field (in dual field mode)
Other display
Safety interlock activated. Malfunction in the external condi‐
tions or in the device itself.
8
COMMISSIONING
90
O P E R A T I N G I N S T R U C T I O N S | S3000 PROFINET IO, S3000 PROFINET IO-OF
8013291/ZA19/2019-11-14 | SICK
Subject to change without notice