Chapter
8
Addendum Operating Instructions
S3000 PROFINET IO/IO OF
28
© SICK AG • Industrial Safety Systems • Germany • All rights reserved
8013291/YY95/2016-02-05
Subject to change without notice
Technical specifications
8
Technical specifications
8.1
Process image S3000 PROFINET IO/IO OF Advanced
The process contains data on four monitoring cases and four field sets.
8.1.1
INPUT
Bit
Description
0.0
Protective field unoccupied
0.1
Warning field unoccupied
0.2
Simultaneous protective field unoccupied
0.3
Simultaneous warning field unoccupied
0.4
Reset required (protective field)
0.5 Reserved
0.6
Reset required (simultaneous protective field)
B
yt
e
0
0.7 Reserved
1.0 Contamination
1.1
Monitoring case valid
1.2
Monitoring case number – Bit 0
1.3
Monitoring case number – Bit 1
1.4 Reserved
1.5 Reserved
1.6 Reserved
B
yt
e
1
1.7 Reserved
2.0 Reserved
2.1 Reserved
2.2 Reserved
2.3 Reserved
2.4 Reserved
2.5 Reserved
2.6 Reserved
B
yt
e
2
2.7 Reserved
3.0 Reserved
3.1 Reserved
3.2 Reserved
3.3 Reserved
3.4 Reserved
3.5 Reserved
3.6 Reserved
B
yt
e
3
3.7 Reserved
Tab. 7: Process image
S3000 PROFINET IO/IO
OF
Advanced INPUT