NOTE
The procedure for using the Quickstart function in the SOPAS ET configuration software
is described in the device-specific Quick Start Guide. A printed copy of this guide is
enclosed with the device. The Quick Start Guide can also be found online at:
•
•
RFU63x
The procedure described in the Quick Start Guide is based on the RFU63x-13100 or
RFU63x-04100 device variant (region assignment of both: Europe) and the default set‐
tings. The permissible ambient temperature range is 0 °C to +60 °C.
For temperatures below 0 °C, see the relevant instructions in the “Mounting” and “Elec‐
trical installation” chapters of these operating instructions.
RFU65x
The procedure described in the Quick Start Guide is based on the RFU65x-10100
device variant (region assignment: Europe) and the default settings. The permissible
ambient temperature range is 0 °C to +60 °C.
For temperatures below 0 °C, see the relevant instructions in the “Mounting” and “Elec‐
trical installation” chapters of these operating instructions.
7.4
Initial commissioning
The device is adjusted to the application situation on site using the SOPAS ET configura‐
tion software on the PC. The default factory settings of the device are the starting point
for this. Their parameter values (configuration data) can be adapted in the working
memory of the device for optimization purposes. To do so, the user creates an applica‐
tion-specific parameter set using the SOPAS ET configuration software, or modifies the
parameter set at a later time as required. He then loads the current parameter set to
the permanent parameter memory of the device.
Memory organization for parameter set
Parameter set in the
main memory of the
device
8
Permanently saved
parameter set of the
device
5
Factory default setting of
the device
9
Device
2
Optional:
1
PC with SOPAS ET
Configuration Software
3
MicroSD memory card
4
Parameter memory module
CMC600
7
Volatile memory
â
Opened project file
with current parameter
set of the device
ß
Volatile memory
â
Non-volatile memory
á
Non-volatile memory
á
Saved project file (*.sopas)
with archived parameter
set of the device
à
Data base on hard drive
(non-volatile memory)
ã
‒ and/or ‒
6
Permanently saved
parameter set of the
device
5
Non-volatile memory
á
Permanently saved
parameter set of the
device
5
Non-volatile memory
á
Figure 39: Saving the parameter set and configuration using SOPAS ET
1
Optional
2
Device
3
PC with SOPAS ET configuration software
4
MicroSD memory card
5
Permanently saved device parameter set
6
and/or
COMMISSIONING
7
8014335/ZTL9/2018-10-14 | SICK
O P E R A T I N G I N S T R U C T I O N S | RFU63x, RFU65x
73