background image

Quick‐

start

Q U I C K S T A R T

e n

1

About this document

The purpose of this Quickstart is to allow you to commission the RFU620-10xxx

RFID read/write device (UHF) quickly and easily and to achieve initial read results

with transponders.
The Quick Start Guide is valid for all the regional radio device variants listed: 

see

Device overview, page 8

.

In the following, the Quick Start Guide refers to the RFU620-10xxx (UHF) RFID

read/write device simply as “device”. If variants are to be differentiated in the

regional assignment, the respective device name RFU620-10x

xx

 is specified (xx =

regional assignment).
The Quick Start Guide describes the commissioning process for an application

with 

one

 device in an ambient temperature range of 0 °C to +50 °C.

Commissioning is carried out as an example for the RFU620-10100 device vari‐

ant (Ethernet variant, Europe region and other countries if necessary, 

see Device

overview, page 8

). The basis is the basic parameter setting of the device. The

optional CDB620-001 connection module handles the industrial-standard signal

distribution for the device depending on the device itself. Other connection mod‐

ules are available. With the exception of the electrical connection, other device

variants are commissioned in the same way.
All rights reserved. Subject to change without notice.

Supplementary and other relevant documents

Information, such as application examples and downloads of associated docu‐

ments (e.g. operating instructions) and software, can be found on the SICK prod‐

uct page on the Internet at

www.sick.com/RFU62x

. For an overview 

see Sources

for obtaining more information, page 9

 in this Quick Start Guide.

More detailed information on mounting and electrically installing the device as a

stand-alone unit than provided in this Quickstart is available in the RFU62x RFID

read/write device (UHF) operating instructions. The operating instructions add the

following information to the Quick Start Guide:

Requirements and notes for mounting and electrical installation at operating

ambient temperatures below 0 °C

For applications in widely distributed systems: Notes on the suppression of

ground potential equalizing currents

Electrical wiring plans for the optional connection modules of the CDB and

CDM product families when used in conjunction with the RFU620-101xx and

RFU620-104xx devices

2

Safety information

This chapter is dedicated to the safety of commissioning personnel and the

operator of the system in which the device is integrated.

Read this Quickstart carefully to familiarize yourself with the device and its

functions before commissioning the device. The Quickstart is considered a

part of the device and must be kept in an accessible location in the immedi‐

ate vicinity of the device at all times!

Electromagnetic radiation

WARNING

Health hazard as a result of high-frequency electromagnetic radiation!

The 

RFU620-10x00

 (Europa region and possibly other countries) is designed

for operation in accordance with ETSI EN 302208. During operation, the

human exposure regulations covered by EN 50364 must be observed.

Limit human exposure to electromagnetic fields. Suitable safety dis‐

tances must be maintained during both short-term and long-term work

in the radiation range of the integrated antenna. Minimum distances to

be maintained between the antenna and the human body during long-

term transmission: 10 cm and maximum radiation power of the antenna

of 250 mW ERP (24 dBm) as per ETSI.

The 

RFU620-10x01

 (USA region and possibly other countries) satisfies the limit

values of the FCC for exposure to radiation in an uncontrolled environment.

During operation, a safety distance of at least 20 cm must be main‐

tained between the antenna and the human body.

Complete region assignment of the RFU620-10x0x 

see Device overview,

page 8

.

Conditions for specified enclosure rating

To ensure compliance with the IP67 or IP65 enclosure rating of the device

during operation, the following requirements must be met. If these require‐

ments are not met, the device does not fulfill any specified enclosure rating.

°

The joint side cover for the USB interface and the memory card slot is

screwed tightly onto the device. Recommended tightening torque for

the cover screws: 60 Ncm ± 5 Ncm.

°

The cables plugged into the electrical M12 connections are screwed

tight.

°

Any unused M12 connections must be sealed with screw-on protective

caps (for male connectors) or plugs (for female connectors) as sup‐

plied.

°

Only operate the device without a cover for a short period while insert‐

ing or removing the memory card or temporarily using the USB inter‐

face. During this time, protect the device against moisture and dust.

Opening the screws of the device housing will invalidate any warranty claims

against SICK AG. For further warranty provisions, see the General Terms and

Conditions of SICK AG, e.g. on the delivery note of the device.

Standard IP technology

NOTE

SICK uses standard IP technology in its products. The emphasis is

placed on availability of products and services.
SICK always assumes the following prerequisites:

The customer ensures the integrity and confidentiality of the data

and rights affected by its own use of the aforementioned products.

In all cases, the customer implements the appropriate security

measures, such

 

as network separation, firewalls, virus protection,

and patch management.

2.1 Intended use

The RFU620 RFID read/write device is an intelligent ID sensor from the RFU6xx

(UHF) product family. Version (working range): Mid Range.
The stationary device automatically identifies wireless-based data cards

(transponders) on stationary and moving objects. The device also supports data

card management.
The compact read/write device has an (internal) antenna integrated in the hous‐

ing. The device processes the data of all standard passive transponders in accor‐

dance with ISO/IEC 18000-6C and EPCglobal UHF C1G2 in the regional UHF car‐

rier frequency range.
Intelligent process logic enables processing either as a stand-alone solution or as

part of a group in a network with several devices. The device sends the read

results to a higher-level computer via its host interface. The computer coordinates

further processing of the data in the process.
The device receives corresponding commands for data card management (write,

read, etc.) via its host interface.
The RFU620-10xxx product family consists of 3 variant lines. The devices of vari‐

ous lines differ, among other things, in the number and type of data interfaces as

well as in the designs of the electrical connections:

RFU620-101xx: Ethernet variant with integrated heating for ambient temper‐

atures as low as –40 °C

RFU620-104 xx: Serial variant

RFU620-105 xx: PoE variant (PoE: Power-over-Ethernet)

Each device variant line contains device variants with reference to the regional

assignment, 

see Device overview, page 8

.

NOTE

The device approval was granted for a specific region. The region assignment

cannot be changed.

Only use the device in the region and the country for which it has been

approved.

When reselling the device, inform the buyer of the fixed region assign‐

ment.

Should the device be passed on to a third party, these operating instruc‐

tions and the Quick Start Guide should be handed over with it.

For country-specific particulars to consider when operating the device,

see Operational restrictions, page 9

.

Intended use also includes compliance with all information in this Quickstart and

the supplementary RFU62x RFID read/write device (UHF) operating instructions.

8015928/10XW/2019-12-12/en

RFU62x | SICK

1

8015928/10XW/2019-12-12

www.sick.com

RFU62x

SICK AG

Erwin-Sick-Straße 1

D-79183 Waldkirch

Summary of Contents for RFU62 Series

Page 1: ...ody Complete region assignment of the RFU620 10x0x see Device overview page 8 Conditions for specified enclosure rating To ensure compliance with the IP67 or IP65 enclosure rating of the device during...

Page 2: ...rd Possible causes The memory card does not contain any data The content is not readable The memory card is defective Lights up Orange 1 A function is started with SOPAS ET which requires a memory car...

Page 3: ...ounted using all 2 M6 or 4 M5 blind tapped holes pro vided see Device view page 2 If necessary provide stable mounting equipment with sufficient load bearing capacity and appropriate dimensions for th...

Page 4: ...supply voltage is polarity reversed this will not cause any damage pro vided that the following conditions are met for the device The device is not connected in an electrically conductive manner eithe...

Page 5: ...re rating for the connecting cable of the device use the optional rubber seal part no 4038847 between the male and female con nectors of the 15 pin D Sub HD male connector and screw the pin connectors...

Page 6: ...5 Hz 1 transponder in field Flashing quickly f 2 5 Hz 2 transponders in field Flashing faster f 5 Hz More than 2 transponders in field NOTE Quickstart mode is not intended to be used during normal ope...

Page 7: ...met during device operation 11 2 Interfaces RFU620 101xx RFU620 104xx RFU620 105xx Ethernet Protocol TCP IP Function host data output of the read result Function Aux for service 1 Data transmis sion r...

Page 8: ...ts 3 At full transmitting power and with a typical loading of the 2 digital outputs of 100 mA each and with a 30 V DC supply voltage 4 At full transmitting power active heating from 25 C and with a ty...

Page 9: ...ction Mexico 1 IFETEL note Operation is subject to the following two conditions 1 This device must not pro duce any harmful faults and 2 this device must be able to withstand faults including faults t...

Page 10: ...native to Ethernet host port Adapter cable male connector M12 4 pin D coded male connector RJ 45 8 pin For CDB620 and CDM420 Adapter cable female connector M12 17 pin A coded male connector D Sub HD 1...

Page 11: ...Ethernet Aux 1 USB USB 4 USB Aux 2 for temporary use only 3 1 Adapter cable male connector M12 8 pin X coded male connector RJ 45 8 pin 2 Adapter cable male connector USB Micro B type male connector...

Reviews: