6.4 First startup
The TCP-IP protocol at the PC has to be active to enable communication via TCP-IP.
The SOPAS-ET configuration software optimises the RFH620 to the reading/writing
conditions on site. Starting point for this is the factory default setting which can be
adjusted to RFID device. The SOPAS-ET configuration software is used to create an
application-specific parameter set which can be loaded permanently into the RFH620
and saved/archived as a project file (spr file with configuration data) on the PC.
If the RFH620 is containing the Micro SD cloning card the parameter set is saved
permanently to the MicroSD card with every permanent storage of the parameter set to
the RFH620.
After the RFH620 is restarted, the data from the cloning card automatically transferred
to the RFH620. As such, RFH620 can be exchanged, for example, without losing
configuration data (see chapter “Replacing a RFH620”).
6.4.1 Overview of the startup procedure
¾
Connect data interfaces of the PC and the RFH620
¾
Start the SOPAS-ET configuration software and create a new project file
¾
Configure the scan assistant (activate PC communication)
¾
Establish communication with the RFH620
¾
Accept current configuration of the RFH620 in the project tree
¾
Log on as an "Authorized client" to the RFH620
¾
Configure the RFH620 for use
¾
If necessary, apply the "Event Monitor" diagnosis tool
¾
Load the optimised configuration into the RFH620 and save permanently
¾
Save the project file with the configuration data of on the PC