x
4.3 Installation location
The following aspects are relevant for the selection of the installation location:
¾
Reading distance to the transponder and aperture angle
α
¾
Avoiding metal surface in front of antenna opening
Furthermore, the distance between the RFH620 and the host computer and the distance
to the connection module has to be taken into account (see chapter Electrical installation
preparation, chapter Installing connection module CDB620 or CDM420).
4.4 Installation of the RFH620
4.4.1 Installing the RFH620
Damage to the device!
The maximum thread reach of the two blind hole taps M6 is 6 mm (0.2 in). Longer bolts
will damage the device.
¾
Use bolts of a suitable length.
1. Preparing base for the installation of the RFH620 holder (see chapter accessories)
2. Place the transponder at the designated position where the reading should be taken in
the RFID reading field (no conveyor movement).
3. Visually align the RFH620 to the transponder..
4. Installing the RFH620 holder on the base.
5. Screw M6 bolts through the holder and into the bar code scanner's blind hole taps and
gently tighten them.
6. Adjusting the RFH620, see chapter adjusting the RFH620