Operating instructions
Chapter
5
RFID Access Management
8018582/2015-11-03
Operating instructions| SICK
35
Subject to change without notice
Electrical installation
5.2.2
Connection to the network
The connection of the RFID interrogator to the configuration PC is established directly via
the Ethernet connection on the device.
1. Connect the male connector of the Ethernet cable to the
Ethernet
female connector
and screw together the plug connector.
2. Route the Ethernet cable from the RFID interrogator to the switch.
3. There, insert the RJ45 male connector into an open female connector.
If the device cannot be permanently connected to the configuration PC due to space
restrictions, the device must be manually configured later on via a direct connection to
the PC.
5.3
Connecting RFID interrogators via a connection module
The connection between the RFID interrogator and connection module is established via
a 17-pin connecting cable. All other cables (power supply, switching outputs, etc.) are
connected to the terminals via cable glands. For details of the terminal pin assignment,
see the cover of the connection module.
The connection of the RFID interrogator to the configuration PC is established directly via
the Ethernet connection on the device.
Fig. 22: Connecting RFID interrogators via a connection module
5.3.1
Connecting an RFID interrogator to a connection module
1. Connect the female connector of the connecting cable to the M12 male connector of
the connection module and screw together the plug connector.
2. Run the cable to the connection module.
3. Connect the male connector of the connecting cable to the M12 female connector of
the connection module and screw together the plug connector.
Note