Operating instructions
Chapter
10
RFID Access Management
8018582/2015-11-03
Operating instructions| SICK
101
Subject to change without notice
Technical data
10.1.3
RFU62x RFID interrogator data sheet
Frequency range
UHF (860 ... 960 MHz)
Carrier frequency
Europe: 865.6 ... 867.6 MHz
USA/Canada/Mexico: 902.75 ... 927.25 MHz
Australia: 920.25 ... 925.75 MHz
Output power
250 mW (ERP, 24 dBm)
European radio equipment
approval
(EN 302 208-2 V1.4.1, firmware version V1.1 and higher)
RFID standard
EPCglobal UHF Class 1 Generation 2, ISO/IEC 18000-6 C
Scanning range
Max. 1 m *
Antenna
Integrated (circular polarized, axial ratio typ. 2 dB, 100°
aperture angle, front-to-back ratio > 7 dB)
Service functions
Parameter cloning via integrated microSD memory card
slot or externally via CMC module in CDB62x
Other functions
Cloning function (SD card or system), diagnostics,
updateable firmware, flexible data output format
(freely configurable), heartbeat, triggering
Data interfaces
Ethernet 10/100 Mbit/s, RS-232, RS-422/485
Power connection
10 V DC ... 30 V DC
Power consumption
8 W, with heating typ. 16 W
Rel. air humidity
90% non-condensing
Operating temperature
-40 °C to +50 °C
Weight
780 g
Dimensions
137 mm x 131 mm x 56 mm
* Depending on tag used and ambient conditions.
Tab. 21: RFU62x RFID interrogator data sheet