4 Product description
A
B
C1
C2
E2
E1
D1
D2
Display areas
A
B
C1/C2
D1/D2
E1/E2
Display mode
Indication of the
applied pressure
Key symbol if the
keypad is locked,
unit of pressure set
Switching thresh-
olds set
Output state for
switching output
1/2
Set value of
switching thresholds
Programming mode
Value of the
selected parameter
Selected parameter
Additional infor-
mation
Output state for
switching output
1/2
Set value of
switching thresholds
Table 2: Indicators in display areas
Once the set switching points (SP1/2, RP1/2, FH1/2, or FL1/2) have been reached, the color of the respec-
tive switching point display areas changes between green and red.
The color change can be set using the "DISC" function:
•
Red if the switching point is not reached or undershot, or if the applied pressure is within the defined
window, and green if the switching point is exceeded or if the applied pressure is outside the window
("DISC" function: OD)
•
Red if the switching point is exceeded or if the applied pressure is outside the defined window, and green
if the switching point is not reached or undershot, or if the applied pressure is within the window (“DISC”
function: DU)
Figure 6: Display areas