Figure 74: Switch-off tests
t
S
S
= 40 ms
OSSD 1.A
V
t
OSSD 1.B
V
t
≤ 300 µs
≤ 300 µs
S
4 × t
Figure 75: Duration and time offset for the switch-off tests in an OSSD pair
t
S
S
= 40 ms
13.6
Sensing range
The effective protective field range depends on the object resolution that has been set.
Table 33: Protective field range
70 mm
4.00 m
50 mm
3.50 m
Range for warning fields
For non-safety applications (warning fields), the safety laser scanner has a larger range
than the maximum protective field range. The requirements for size and remission of
objects to be detected are illustrated in the following graphs as a function of the
desired range.