When the start procedure is complete, the status LEDs and the display show the safety
laser scanner’s current operational status.
1
2
3
4
Figure 61: Status LEDs
Table 15: Status LEDs
Number
Function
Color
Meaning
1
Red
Lights up red when the OSSD pair is
in the OFF state.
2
Green
Lights up green when the OSSD pair
is in the ON state.
3
Yellow
Shines yellow if at least one warning
field is interrupted.
4
Yellow
Setup with reset: Flashes if the
restart interlock has been triggered.
Configuration with automated restart
after a time: Lights up while the con‐
figured time to restart expires.
The OFF state and ON state light emitting diodes can be found in multiple locations on
the safety laser scanner. 3 additional sets are arranged in pairs on the base of the
optics cover. So the light emitting diodes can also be seen in many cases when it is not
possible to see the display, e.g. due to the mounting situation or because it is hidden
from the operator’s position.
More information about what the light emitting diodes mean and the symbols and infor‐
mation shown on the display:
see "Troubleshooting", page 116
.
8.4
Thorough check
Requirements for the thorough check during commissioning and in certain situations
The protective device and its application must be thoroughly checked in the following
situations:
•
Before commissioning
•
After changes to the configuration or the safety function
•
After changes to the mounting, the alignment or the electrical connection
•
After exceptional events, such as after manipulation has been detected, after
modification of the machine, or after replacing components
The thorough check ensures the following:
•
Compliance with all relevant regulations and effectiveness of the protective device
for all of the machine’s operating modes. This includes the following points:
°
compliance with standards
°
correct use of the protective device
°
suitable configuration and safety function
°
correct alignment
COMMISSIONING
8
8023152/160F/2019-11-14 | SICK
O P E R A T I N G I N S T R U C T I O N S | outdoorScan3 Core I/O
103