Troubleshooting
10.1
General faults, warnings, and errors
Possible faults and corrective actions are described in the table below for troubleshoot‐
ing. In the case of faults that cannot be rectified using the information below, please
contact the SICK Service department. To find your agency, see the final page of this
document.
NOTE
To help us to resolve the matter quickly, please note down the details on the type label.
Table 8: Warning and error messages
Question or status
Possible cause
Troubleshooting
LEDs do not light up.
Supply voltage is switched off.
Check the supply voltage.
The
device status
LED
lights up red.
A voltage of 10 V is exceeded
at the analog output in current
mode (e.g. due to an open cir‐
cuit).
Check wiring to the controller,
"Electrical installation", page 28
Dark balance reports
too much stray light.
Measuring head or optical fiber
is contaminated.
Check measuring head and optical
fiber for contamination and clean if
necessary,
Measuring head or optical fiber
is defective.
Check the measuring head and opti‐
cal fiber for damage. Replace if nec‐
essary.
Device does not dis‐
play a valid measure‐
ment.
Device is overdriven.
Increase measuring rate or decrease
lamp intensity,
and
.
Detection window is set incor‐
rectly.
Check detection window settings,
see "Detection window", page 38
.
Measuring object is outside the
focus range.
Position the measuring object in the
measuring range,
.
Measuring head is too slanted
in relation to the measuring sur‐
face.
Change angle between measur‐
ing object and measuring head,
see "Positioning measuring head",
page 44
.
Measuring head is not or
improperly connected.
Check the connection of the meas‐
uring head,
Threshold intensity is too high.
Reduce threshold.
Measuring rate for measuring
object is too high or lamp inten‐
sity is too low.
Reduce measuring rate or increase
lamp intensity,
and
.
Quality of measurement results
is too poor.
Perform dark balance,
Sample is not transparent for
the wavelength range used.
Check the transparency of the sam‐
ple.
10
TROUBLESHOOTING
52
O P E R A T I N G I N S T R U C T I O N S | OD7000
8027188//2022-05-25 | SICK