7
Operation
7.1
General notes
If the device is not able to perform a measurement even though the measuring object is
within the specified measuring range, check the alignment of the device and optimize it
if necessary,
see "Mounting the device depending on application", page 24
. In general,
adjusting the measuring rate can increase the measuring ability for very dark objects,
for example.
To prevent EMC interference, observe the wiring instructions.
7.2
Control elements and status indicators
7.2.1
Indicator lights
12
3
Figure 33: OD5000 control panel
1
Communication LED (link)
2
Status LED (power)
3
Cover screw for reset pushbutton
Table 8: Meaning of the indicator lights
Indicator
Status
Color
State
Communication LED (link)
Ö
Green
Ethernet communication is
active
Status LED (power)
Ö
Blue
Laser off
Ö
Red
Invalid measurement
O
Orange
Measured value valid, out‐
put state for channel A =
high
O
Green
Measured value valid, out‐
put state for channel A =
low
Ö
White
“Find me” is active
Ö
Flashing
O
Permanently on
OPERATION
7
8021391/17Y6/2020-05-11 | SICK
O P E R A T I N G I N S T R U C T I O N S | OD5000
31
Subject to change without notice