Parameter
Value
Factory setting
Display decimal digits
0
,
0.1
,
0.01
0.1
Eco mode
Off
,
10 sec
,
20 sec
,
60 sec
,
300 sec
,
1,200 sec
,
3,600 sec
300sec
Display brightness
10%
,
20%
,
30%
,
40%
,
50%
,
60%
,
70%
,
80%
,
90%
,
100%
30%
Turn display
0°
,
180°
0°
7.4.6.5
Sender
The sender (measuring laser) can be switched off. No measurement is possible with the
sender switched off.
The sender can also be switched on and off via the IN Input.
>
Device
>
>
Sender
>
> Select option >
Parameter
Value
Factory setting
Sender
Off
To
To
7.4.6.6
Output PNP/NPN/PP
The output logic can only be set via the display. The
NPN
setting is incompatible with
most commercially available IO-Link master components.
>
Device
>
>
Output PNP/NPN/PP
>
> Select option >
Parameter
Value
Factory setting
Output PNP/NPN/PP
PNP
NPN
PP
PP
7.4.7
About
Status information
•
Part number
•
Serial number
•
Firmware version
•
Sensor operating hours
•
Sender operating hours
•
Error count
•
Error history
>
Info
>
> Status information
7
OPERATION
46
O P E R A T I N G I N S T R U C T I O N S | OD2000
8026231//2021-11-17 | SICK
Subject to change without notice