Chapter
5
MSC800
62
Operating instructions | SICK
8011540/14B8/2019-06-06
Subject to change without notice
Electrical installation
System/
terminal set
Terminal
Signal
Wire color (numbers
printed on wires)
System 1
KLS1
-X120/
11
DC +24 V (ICD890 camera)
Wire 1: black
-X120/
12
GND (ICD890 camera)
Wire 2: black
-X120/
13
DC +24 V (ICI890_1#1 illumination)
Wire 3: black
-X120/
14
GND (ICI890_1#1 illumination)
Wire 4: black
-X120/
15
DC +24 V (ICI890_1#2 illumination)
Wire 5: black
-X120/
16
GND (ICI890_1#2 illumination)
Wire 6: black
-X120/
17
PE
Green-yellow
System 2
KLS2
-X120/
21
DC +24 V (ICD890 camera)
Wire 1: black
-X120/
22
GND (ICD890 camera)
Wire 2: black
-X120/
23
DC +24 V (ICI890_2#1 illumination)
Wire 3: black
-X120/
24
GND (ICI890_2#1 illumination)
Wire 4: black
-X120/
25
DC +24 V (ICI890_2#2 illumination)
Wire 5: black
-X120/
26
GND (ICI890_2#2 illumination)
Wire 6: black
-X120/
27
PE
Green-yellow
Tab. 36 MSC800-3400: connection of the supply voltage cables for two ICR890 systems