13.7
Data exchange in the network
13.7.1
Assemblies
13.7.1.1
Available data
13.7.1.1.1
Input of the device (output of the control)
Table 42: Input of the device (output of the control)
Name
Use
Data type
Definition
Values
Safety implica‐
tion
ActivateCaseSwitching
BOOL
Monitoring case switch‐
ing
Activates switching
between monitoring
cases. Only valid sig‐
nals are then permitted
for switching between
monitoring cases.
0 = switching
between monitor‐
ing cases not
activated
Safety-relevant
parameter
1 = switching
between monitor‐
ing cases acti‐
vated
ActivateStandbyMode
Additional func‐
tion
BOOL
Activate sleep mode
Activates sleep mode.
0 = no sleep
mode
Parameter with‐
out safety impli‐
cation
1 = sleep mode
BOOL
Control input 1 (A1)
Control input for switch‐
ing between monitoring
cases. Control inputs
can be evaluated com‐
plementarily in pairs or
with a 1-off-n-condition.
0 = logic status
of the control
input is 0
Safety-relevant
parameter
1 = logic status
of the control
input is 1
control input 2 (A2)
…
control input 16 (H2)
BOOL
Control input 2 (A2) …
16 (H2)
Control input for switch‐
ing between monitoring
cases. Control inputs
can be evaluated in a
complementary way in
pairs or with a 1-of-n-
condition.
1)
0 = logic status
of the control
input is 0
Safety-relevant
parameter
1 = logic status
of the control
input is 1
SafeForwardSpeed
INT
Safe speed
Bit 0 ... Bit 11: Safe
speed
Bit 12 ... Bit 15:
Reserved
-2000 ... +2000
= speed in cm/s
Safety-relevant
parameter
SafeSpeedValid
BOOL
SafeForwardSpeed
valid
0 = Invalid speed Safety-relevant
parameter
1 = speed valid
SetMonitoringCaseNoTable1
USINT
Monitoring case num‐
ber (Monitoring case
table 1)
Activates the monitor‐
ing case with the
respective number in
monitoring case table
01.
0 = invalid
Safety-relevant
parameter
1 … 254 = num‐
ber of the moni‐
toring case
13
TECHNICAL DATA
194
O P E R A T I N G I N S T R U C T I O N S | microScan3 Pro I/O
8025424/1ELL/2022-01-21 | SICK