Scan cycle time 30 ms
40 mm
3.00 m
2.30 m
30 mm
2.30 m
1.70 m
Table 32: Protective field range (devices with a max. protective field range of 9.0 m)
50 ms scan cycle time
≥ 150 mm
9.00 m
9.00 m
70 mm
9.00 m
7.00 m
60 mm
8.00 m
6.00 m
50 mm
7.00 m
5.00 m
40 mm
5.00 m
4.00 m
30 mm
4.50 m
3.00 m
Scanning range of the reference contour field
The effective scanning range of the reference contour field is the same as the protec‐
tive field range.
Scanning range of the contour detection field
The effective scanning range of the contour detection field is the same as the protective
field range.
13.7
Dimensional drawings
1
2
112
Ø 99,5
≤ 200
M5×7,5
85
44
12
135,1
111,1
300
47,1
47,9
40,1
≥ 25
≥ 25
22
36,1
36,9
3
4,4
24,5
Figure 75: Dimensional drawing
All dimensions in mm.
1
Mirror rotational axis
2
Scan plane
3
Required viewing slit
13
TECHNICAL DATA
134
O P E R A T I N G I N S T R U C T I O N S | microScan3 Core I/O AIDA
8017784/1ELL/2022-01-21 | SICK
Subject to change without notice