Table 21: Compatibility
Label on the device
Label on the system plug
Compatible
–
–
Yes
–
Only compatible with Rev ≥ 1.1.0
Information is available
from your SICK subsidiary.
Rev 1.1.0 (or higher)
–
Yes
Rev 1.1.0 (or higher)
Only compatible with Rev ≥ 1.1.0
Yes
13.3
Data sheet
13.3.1
microScan3 Core I/O AIDA
Features
Table 22: Features
microScan3 Core I/O AIDA
Devices with a max. protec‐
tive field range of 4.0 m
≤ 4.0 m, details:
Devices with a max. protec‐
tive field range of 5.5 m
≤ 5.5 m, details:
Devices with a max. protec‐
tive field range of 9.0 m
≤ 9.0 m, details:
Scanning range of the refer‐
ence contour field
Same as protective field range,
Scanning range of the con‐
tour detection field
Same as protective field range,
Distance measurement range
Devices with a max. protec‐
tive field range of 4.0 m
≤ 40 m
Devices with a max. protec‐
tive field range of 5.5 m
≤ 40 m
Devices with a max. protec‐
tive field range of 9.0 m
≤ 64 m
Fields
≤ 4
Simultaneously monitored
fields
≤ 4
Field sets
≤ 4
Monitoring cases
1
Scanning angle
275° (–47.5° … 227.5°)
30 mm, 40 mm, 50 mm, 60 mm, 70 mm, 150 mm, 200 mm
1)
Angular resolution
Devices with a max. protective field range of 4.0 m
Scan cycle time 30 ms 0.51°
Scan cycle time 40 ms 0.39°
Devices with a max. protective field range of 5.5 m
Scan cycle time 30 ms 0.51°
Scan cycle time 40 ms 0.39°
Devices with a max. protective field range of 9.0 m
13
TECHNICAL DATA
126
O P E R A T I N G I N S T R U C T I O N S | microScan3 Core I/O AIDA
8017784/1ELL/2022-01-21 | SICK
Subject to change without notice