98
8024638/AE00/V1-0/2019-09| SICK
S E R V I C E M A N U A L | MCS200HW
Subject to change without notice
5
REPAIRS
5.3.4
Fitting the complete sender/receiver unit
1
Push sheet metal cover 1 in with foam insulation.
2
Insert the sleeves and tighten sheet metal cover 5.
3
Attach sheet metal covers 4 to 2.
4
Screw all sheet metal covers tight.
5
Fit the outer sheet (
see Fig. 140 “Sender/receiver unit, outer plate”, page 96
▸
Guide the power supply cable through the recess.
▸
Tilt the sheet slightly when attaching.
6
Connect the hose connections of the sender/receiver unit to the outer sheet.
7
Attach the inner bracket and screw tight (
see Fig. 138 “Transmit/receive unit, front
8
Screw the templates tight on the rear side (
see Fig. 137 “Sender/receiver unit, rear
9
Hook the sender/receiver unit with the mushroom head brackets into the device
cabinet.
10
Screw the sender/receiver unit tight on the device cabinet (
receiver unit, fastening screws”, page 94
).
11
Connect the plug connections.
12
Screw the electronics housing cover tight.
13
Replace the drying agent (
see Chapter “Replacing the drying agent”, page 44
14
Close the cover of the sender/receiver unit (optional) and screw tight.
5.3.5
Replacing the fan
1
Disconnect the MCS200HW power supply.
2
Remove the electronics housing cover and fan cover (
see Chapter “Removing the elec-
tronics housing cover”, page 88
).
3
Disconnect the fan power supply.
Tools required
Phillips screwdriver
6 mm Allen key
2.5 mm Allen key
Tweezers
Tools required
Phillips screwdriver
Spare parts set No.
Contents
2099749
Fan with filter unit for electronics unit