Enclosure rating
Housing without electrical connection
ISO 16750-4: EN 60529
IP67 30 min - 1 m
Housing with cable connector
ISO 16750-4: EN 60529
IP67 30 min - 1 m
M12 male connector
ISO 16750-4: ISO 20653
IP69K with coupling on;
Spraying: 30 sec. / 100 bar / 80 °C
Temperature ranges
Operating temperature (operating condition)
Allowing for fluid temperature and intrinsic heat‐
ing of the electronics
- 40 °C … +105 °C
Ambient temperature (fluid)
- 30 °C … +95 °C
Permissible relative humidity
EN60068-2-30: 90% r.H. (condensation not permitted)
Storage
- 20 °C … +85 °C (r.H. 55%)
Resistance to shocks
Drop test
ISO 16750-3: IEC 60068-2-31
Single shock
ISO 16750-3: IEC 60068-2-27: 100 g, 11 ms
Continuous shocks, 1,000 shocks per spatial
axis
ISO 16750-3: IEC 60068-2-27: 50 g, 11 ms
Resistance to vibrations
(Ø 10 mm pressure pipe)
Sine
ISO 16750-3: IEC 60068-2-6
10 ... 55 Hz (3.5 mm pp)
55 ... 2,000 Hz 20 g (24 hrs)
Sine-on-random
ISO 16750-3: IEC 60068-2-80
100 ... 440 Hz 11.3 g (r.m.s.)
10 ... 2,000 Hz 18.1 g (r.m.s.)
Random
ISO 16750-3: IEC 60068-2-64
10 Hz … 2,000 Hz 20 g (r.m.s.) (48 hrs)
Resonance peaks removed
Hydraulic pressure
Pressure pipe, Ø 10 mm
Pressure pipe, Ø 7 mm
Operating pressure P
N
400 bar
320 bar
Max. overload pressure during operation
(P
N
x1.2)
480 bar
380 bar
Max. test pressure in cylinder (P
N
x1.5)
600 bar
480 bar
10.2
Dimensions of sensor
L ±0.5
(0.02)
27.2
(1.07)
21.2
-0.2
(0.83
-0.01
)
11.5
(0.45)
Ø
4
8
f
7
(1
.8
9
)
Ø
2
4
(0
.9
4
)
Ø
1
0
(0
.3
9
)
30
(1.18)
1
2
Figure 22: MAX48 overall dimensions
1
Measuring range
10
TECHNICAL DATA
32
T E C H N I C A L I N F O R M A T I O N | MAX48
8021473/2017-08-08 | SICK