FAULT DIAGNOSIS
9
111
8020065-ZLP4/2017-08-10|SICK
Subject to change without notice
O P E R A T I N G I N S T R U C T I O N S | Master Data Analyzer
1. Press
OK
to confirm you have seen the error message. The window containing the
message closes. The circle symbol for the measurement status indicator is red.
If you accidentally close the window without having read the error message, you can
display the notes again. To do this, click on the red circle.
2. Rectify the error. For this example: Position the entire object in the measurement field.
3. In the operating mode with bar code scanning, scan the bar code with the hand-held
scanner or enter it manually. This creates a new measurement data set.
In the operating mode without bar code scanning, the object has to be removed from
the glass panel and repositioned again.
4. Now move the measurement gantry over the object.
Once the volume has been measured, all measured values appear on the display and
are transmitted by the MSC800 controller to the customer system via the defined
interface.
9.2.1.2
Overview of status messages
The following tables provide an overview of all system messages with their error codes
and a description of the error.
Messages about the system status indicate, for example:
•
That the light grids are contaminated and their optical performance is severely
restricted.
•
That the Master Data Analyzer’s components cannot be addressed (e.g., the system is
not connected to the light grids or the MSC800).
Color
Level
Code
(dec./hex)
Name
Brief information
Status description
Info
0000/ 0000
System
The system is ready for
measuring.
-
Warning
0001/ 0001
System error
Sorry, something went wrong.
Please try again or contact your
service partner.
Error
0678/ 02a6
Light grid error
No connection to light grid 1.
Please contact service partner.
Error
0679/ 02a7
Light grid error
No connection to light grid 2.
Please contact service partner.
Warning
0680/ 02a8
Scale error
No connection to scale.
Please contact service partner.
Error
0841/ 0349
Connection error
No connection to system
controller.
Please make sure the IP
address and port are correct or
contact service partner.
Error
0842/ 034a
System
Trying to connect to controller. -
Tab. 19: Status messages – System status
Note
System status