6
COMMISSIONING
94
8017768/12AX/2019-05-31|SICK
O P E R A T I N G I N S T R U C T I O N S | TIC
Subject to change without notice
6.4.1
Selecting system functions
On the second page, select the initial system functions for vehicle measurement.
Depending on the number of lanes to be monitored, select the number of required system
functions with the plus icon. You can select up to a maximum of three slaves for the
TIC102 and TIC502. The maximum number of four system functions is the limit for the
TIC501.
Also clarify whether the site provides a side strip. This information only affects the
visualization of the measurement site in TEMS Manager.
The system components for counting axles are shown at a distance from the lane. The
master is assigned to the lane which is directly adjacent to the side strips for the TIC102
and TIC502.
The side strip is not included in any system function.
In the following example, we will configure a site with a TIC502 Master and TIC502 Slave.
▸
Click on the plus icon in the master bar. The counter increases by one. The selected
system function appears at the top under
Components
.
▸
The plus icon is then deactivated as only one master can be selected per system.
Side strip