10
Technical data
NOTE
The relevant online data sheet for your product, including technical data, dimensional
drawing, and connection diagrams can be downloaded, saved, and printed from the
Internet:
•
Please note: This documentation may contain further technical data.
10.1
Features
LMS500
LMS511
LMS531
Application
Indoor
Outdoor
Outdoor, Security
Resolution
High resolution
Standard resolu‐
tion, high resolution
(type-dependent)
Standard resolution
Light source
Infrared (905 nm ± 10 nm)
Laser class
1 (IEC 60825-1:2014, EN 60825-1:2014)
Complies with 21 CFR 1040.10 and 1040.11 except for con‐
formance with IEC 60825-1 Ed. 3 as described in Laser Notice
No. 56, dated May 8, 2019.
Aperture angle
190°
Scanning frequency
Lite: 25 Hz ... 75 Hz
PRO/Heavy Duty: 25 Hz ... 100 Hz
Angular resolution
Lite: 0.25°, 0.35 °, 0.50°, 1°
PRO/Heavy Duty: 0.167°, 0.25°, 0.333°, 0.5°, 0.667°, 1°
Exclusively in Interlaced mode: 0,042°, 0,083°
Scan field flatness
Scan field flatness combined: ± 0.72°
Typical conical error: 1 sigma value -0.11° ± 0.10°
Typical tilt: 1 sigma value +0.15° ± 0.08°
Heating
self-heating
Self-heating with additional integrated
heating
Working range
0.2 m … 80 m
Scanning range with 10% radi‐
ance factor
0.7 ... 26 m
0.7 ... 26 m (HR)
1.0 ...40 m (SR)
1.0 ... 40 m
High resolution measurement
accuracy
1.
± 12 mm
–
Standard resolution measure‐
ment accuracy
2.
–
± 24 mm
High resolution spot size
Divergence: 4.7 mrad
On the front screen: 13.5 mm
in 26 m: 136 mm
in 40 m: 202 mm
–
Standard resolution spot size
–
Divergence: 11.9 mrad
On the front screen: 13.5 mm
in 26 m: 322 mm
in 40 m: 489 mm
Number of echoes evaluated
Lite: 2
PRO/Heavy Duty: 5
1.
Measured in test environment (like LMS2xx): Temperature = 23 °C, Remission = 100% at 6 m distance
2.
Measured in test environment (like LMS2xx): Temperature = 23 °C, Remission = 10% at 20 m distance
10
TECHNICAL DATA
84
O P E R A T I N G I N S T R U C T I O N S | LMS5xx
8013796/1ALS/2021-03 | SICK
Subject to change without notice