O P E R AT I N G I N S T R U C T I O N S | L F P C U B I C
8019918 /ZJA6/ 2017-07-20 | S I C K A G
Subject to change without notice
5 9
14
TECHNICAL DATA
14.6
Electrical connection values
Supply voltage.
12 V DC ... 30 V DC
Current consumption
≤ 100 mA at 24 V without output load
Initialization time
≤ 5 s
Protection class
III
Connection type
M12 x 1, 5-pin
M12 x 1, 8-pin
hysteresis
Min. 3 mm, freely configurable
Output signal
1)
4 mA ... 20 mA / 0 V ... +10 V automatically
switchable depending on output load
1)
1 PNP transistor output (Q1) and 1 PNP/NPN
transistor output (Q2) switchable, or 1 PNP
transistor output (Q1) and 3 PNP/ NPN transistor
outputs (Q2 to Q4) switchable (type-dependent)
1)
Signal voltage HIGH
Uv –2 V
Signal voltage LOW
≤ 2 V
Output current
< 100 mA
Inductive load
< 1 H
Capacitive load
100 nF
Temperature drift
< 0.1 mm/K
Output load
4 mA ... 20 mA < 500 ohms at Uv > 15 V
4 mA ... 20 mA < 350 ohms at Uv > 2 V
0 V ... +10 V > 750 ohms at Uv ≥ 14 V
Lower signal level
3.8 mA ... 4 mA
Upper signal level
20 mA ... 20.5 mA
EMC
EN 61326-2-3, 2014/30/EU
1)
All connections are reverse polarity protected. All outputs are overload and short-circuit protected.
2)
Use an energy-limited circuit for the voltage supply as per UL61010-1 3rd Ed., Section 9.3