O P E R AT I N G I N S T R U C T I O N S | L F P C U B I C
8019918 /ZJA6/ 2017-07-20 | S I C K A G
Subject to change without notice
1 1
3
PRODUCT DESCRIPTION
3
Product description
3.1
Product ID
3.1.1
Information on the housing
There is information printed on the housing identifying the sensor and its
electrical connection.
3.1.2
Type code
LFP
x
-
x
x
x
M
x
1
2
3
4
5
6
7
Position
Description
1
Product group
LFP (level sensors)
2
Probe length in mm
0025:
without probe
0200:
in 10 mm increments; rope probe in 1000 mm increments
4000:
4000 mm
3
Process connection/probe version
A:
G ¾ A / single-rod probe 1.4404 interchangeable, 100 °C; 10 bar
B:
¾" NPT / single-rod probe 1.4404 interchangeable, 100 °C; 10 bar
E:
G ¾ A / 3 mm rope probe, 1.4404 interchangeable, 100 °C; 10 bar
F:
¾" NPT / 3 mm rope probe, 1.4404 interchangeable, 100 °C; 10 bar
4
Housing, display/device connection
4:
Plastic housing with display / M12 x 1 / 5-pin male connector
5:
Plastic housing with display / M12 x 1 / 8-pin male connector
5
Application/design
B:
Remote amplifier; length of cable 1 m
C:
Remote amplifier; length of cable 2 m
D:
Remote amplifier; length of cable 3.3 m
N:
Standard
6
Signal output
M:
4 mA ... 20 mA / 0 V ... +10 V reversible
7
Switching output
B:
1 x PNP + 1 x PNP/NPN
C:
1 x PNP + 3 x PNP/NPN
Not all variants of the type code can be combined with each other!