10.5
Ambient data
Type
Lector85x Flex (V2D85xxR-1MCxxxxxxx)
Electromagnetic
compatibility
(EMC)
Immunity: IEC 61000-6-2:2016, EN IEC 61000-6-2:2019
Emission: IEC 61000-6-4:2018, EN IEC 61000-6-4:2019
Vibration resist‐
ance
EN 60068-2-6:2007, EN 60068-2-64:2019
Shock resistance EN 60068-2-27:2008
Ambient operat‐
ing temperature
0 °C … +50 °C
1)
Storage tempera‐
ture
–20 °C … +70 °C
Permissible rela‐
tive humidity
0% ... 90%, non-condensing
Ambient light
immunity
2,000 lx on code
Ambient condi‐
tions
Degree of contamination 2 (according to EN 61010-1)
Altitude
< 5,000 m above sea level
1)
If the ambient operating temperature will be
≥
45 °C, ensure adequate heat dissipation when mounting
the device,
see "Mounting instructions", page 20
.
TECHNICAL DATA
10
8027859//2022-06-22 | SICK
O P E R A T I N G I N S T R U C T I O N S | Lector85x Flex
45