Electrical values
Low: V
in
1)
≤ 2 V; I
in
2)
≤ 0.3 mA
High: 6 V ≤ V
in
≤ 30 V; 0.7 mA ≤ I
in
≤ 5 mA
1)
Input Voltage
2)
Input current
NOTE
Assign the functions for the digital inputs in the device using a configuration tool, e.g.
the configuration software SOPAS ET.
13.3.8
Wiring the external digital inputs of the device in the CDM420-0006
Device = Lector64x = V2D64xx-xxxxYx (Y = A, B or S)
Device = Lector65x = V2D65xx-xxxxYx (Y = A, B or S)
Device
4
CDM420-0006
PNP sensor
7
V
S
GND
3.32 K
6.64 K
V
in
Out
GND
S6
CMC600
3
Aux
(RS-232)
ON
OFF
S6 : SGND
No
YES
S8 : CMC
17 SGND
8 Shield
39 +24 V*
A
Aux In
B
+24V*
“External
input
C
”
5
SensGND
Trigger sensor
1
8
E.g. photo-electric
switch
6
2
Figure 38: Trigger sensor supplied with power by connection module CDM420-0006
1
Trigger sensor, e.g. for read cycle generation
2
Input voltage V
in
3
The optional CMC600 parameter cloning module is required in the connection module in order to be able to use the
additional external digital inputs and outputs of the device
4
Device
5
Logical “External input” in the device
6
e.g. photoelectric sensor
7
PNP sensor
8
Supply voltage V
S
ANNEX
13
8016185/19E9/2020-10-21 | SICK