NOTE
The device transmits the statuses of its logical outputs to the CMC600 via its serial
data interface. The CMC600 converts the statuses into switching signals on its physical
digital outputs.
The digital outputs are not suitable for time-critical applications.
Characteristic data of the digital outputs
Table 27: Characteristic data of the digital outputs “External output 1” and “External output 2”
Type
Switching
Switching behavior
PNP switching to supply voltage V
S
Default settings in the device: no function, logic: not inverted (active
high)
Properties
•
Short-circuit pro temperature protected
•
Not electrically isolated from the supply voltage V
S
Electrical values
0 V ≤ V
out
1)
≤ V
S
(V
S
−1.5 V) ≤ V
out
≤ V
S
at I
out
2)
≤ 100 mA
1)
Output voltage.
2)
Output current.
NOTE
Assign the functions for the external digital outputs in the device using a configuration
tool, e.g., the SOPAS ET configuration software.
13.3
Connection diagrams of connection module CDM420-0006
13.3.1
Connection of the device to CDM420-0006
Device = Lector64x = V2D64xx-xxxxYx (Y = A, B or S)
Device = Lector65x = V2D65xx-xxxxYx (Y = A, B or S)