![SICK Lector64x Flex Operating Instructions Manual Download Page 25](http://html1.mh-extra.com/html/sick/lector64x-flex/lector64x-flex_operating-instructions-manual_1263971025.webp)
5
Mounting
5.1
Mounting instructions
•
Observe the technical data.
•
Protect the sensor from direct and indirect sunlight.
•
To prevent condensation, avoid exposing the device to rapid changes in tempera‐
ture.
•
The mounting site has to be designed for the weight of the device.
5.2
Overview of mounting procedure
The mounting of the device is divided into the following steps:
•
Mount the device.
•
Align the device with the object.
•
Connect the device to interfaces and supply voltage.
•
Adjust the device.
5.3
Preparation for mounting
5.3.1
Installation requirements
For devices with the type code V2D6xxx-xxxxx
H
x, the EN61000-6-4 standard applies.
Note the following for these devices:
NOTICE
Radio interference may occur when the device is used in residential areas!
Only use the device in industrial environments (EN 61000-6-4).
•
Typical space requirement:
see "Field of view diagrams", page 29
and type-spe‐
cific dimensional drawing.
•
Comply with the technical data, such as the permitted ambient conditions for
operation of the device,
•
Ensure good dissipation of excess heat from the device to the surroundings, in
particular at higher ambient temperatures. Ensure that there is good heat transfer
from the device, for example via the bracket to the mounting base, or ensure that
the back of the device is a sufficient distance from the wall of a housing.
•
The device must be mounted using the tapped blind holes provided for this pur‐
pose, or using the sliding nuts.
•
Mount the device in a shock and vibration insulated manner.
•
Make sure the device has a clear view of the codes.
Auxiliary equipment required
■
Mounting system with sufficient load-bearing capacity and suitable dimensions.
■
Four or two M5 screws for mounting the device on a mounting system supplied
by the customer. The screw length depends on the mounting base (wall thickness
of the bracket). When using an optional SICK mounting system, the screws for
mounting the device are included with delivery.
■
Tool and tape measure.
5.3.2
Mounting systems
Mount the device on the mounting system by means of two tapped blind holes (M5) or
sliding nuts.
The threaded mounting holes are located on the rear of the device.
MOUNTING
5
8016185/19E9/2020-10-21 | SICK
O P E R A T I N G I N S T R U C T I O N S | Lector64x/65x Flex, Lector65x Dynamic Focus
25