9.5
Returns
b
Do not dispatch devices to the SICK Service department without consultation.
b
The device must be sent in the original packaging or an equivalent padded pack‐
aging.
NOTE
To enable efficient processing and allow us to determine the cause quickly, please
include the following when making a return:
■
Details of the contact person
■
Description of the application
■
Description of the fault that occurred
9.6
Replacing the device
Replacing a device with transfer of the current configuration data
The current configuration data of the device to be replaced can be transferred to a
replacement device in several ways. The configuration data of the device is combined
as a parameter set. The replacement device saves the parameter set to the permanent
parameter memory.
Prerequisites:
•
The replacement device is a device of the same type.
•
The current configuration data of the device to be replaced is accessible in a stor‐
age medium outside the device.
The available options depend on the backup concept chosen by the user at the time of
installation and configuration of the device to be replaced.
The first three methods are performed automatically by the device. The fourth method
is operated manually by the user.
Available options for transferring the configuration data:
1
Transfer of the current configuration data using the optional microSD memory
card removed from the device to be replaced.
Prerequisite:
If there is sufficient memory capacity on the microSD memory card, the configura‐
tion data from the last save operation in the device with the
Permanent
option was
automatically saved on the memory card.
It is not necessary to connect a computer with the SOPAS ET configuration soft‐
ware for transfer to the replacement device.
2
Transfer of the current configuration data using the optional CMC600 parameter
cloning module in the optional CDB or CDM connection module.
Prerequisite:
The device to be replaced was continuously operated connected to the connection
module. If the optional microSD memory card and CM600 parameter cloning mod‐
ule are present, the configuration data in the parameter cloning module has
higher priority.
It is not necessary to connect a computer with the SOPAS ET configuration soft‐
ware for transfer to the replacement device.
3
Transfer of the current configuration data using the parameter memory in the
optional CDF600 bus connection module.
Prerequisite:
The device to be replaced was continuously operated in proxy mode connected to
the bus connection module. If the optional microSD memory card and bus connec‐
tion module are present, the configuration data in the bus connection module has
higher priority.
TROUBLESHOOTING
9
8022502/15NT/2020-02-11 | SICK
O P E R A T I N G I N S T R U C T I O N S | Lector621
61
Subject to change without notice