285
or
parameter can be used to select a second condition for deactivating the digital
output.
In order for the digital output to be deactivated, one of the conditions must be met.
•
---
: No second condition selected
•
MATCH 1 CONDITION
: The output is deactivated if the code that has been read corre‐
sponds to the
MATCH 1 CONDITION
match code.
•
MULTICODES1 CONDITION
: The output is deactivated if the number of codes that have
been read corresponds to the number specified by the
MULTICODES1 CONDITION
.
•
TEACH-IN1 CONDITION
: The output is deactivated if the code that has been read corre‐
sponds to the
TEACH-IN1 CONDITION
match code.
•
TEACH-IN2 CONDITION
: The output is deactivated if the code that has been read corre‐
sponds to the
TEACH-IN2 CONDITION
match code.
286
or Teach-in via function buttons
If the
or Teach-in via function buttons
parameter is activated, the match code teach-in
process can also be started by pressing the pushbuttons on the sensor. In this case, no
signal is required to prepare for the teach-in process.
287
Online Image
The captured images are displayed on the
tab.
The display enables you to look at the images in detail and assess the quality of the
shots. By modifying the configuration and comparing each of the images captured, you
can optimize the reading properties and the position of the sensor.
NOTE
The reading results are displayed in the
.
So that the current contrast setting can be evaluated, the identified codes are dis‐
played in different colors:
•
Green (excellent): Contrast between 55% and 100%
•
Yellow (good): Contrast between 20% and 55%
•
Red (poor): Contrast less than 20%
288
Folder name
parameter is used to select the default name for the image folder.
•
SERIAL NUMBER
: The image files are stored in a folder with the same name as the
sensor's serial number.
•
DEVICE NAME
: The image files are stored in a folder with the same name as the value
set for the
parameter. Assigning appropriate device names makes it easy to
distinguish between file names when there are several similar devices (e.g., on a
network).
Name
parameter can be used to define a device name for the sensor. The image
files generated by the sensor are stored in a folder with the same name. Assigning
appropriate device names makes it easy to distinguish between file names when there
are several similar devices (e.g., on a network).
SOPAS PARAMETER OVERVIEW
98
O N L I N E H E L P | Lector62x
8013778/YPV6/2016-01-14 | SICK
Subject to change without notice