279
Usage PLC-Input Bit1
parameter specifies how the PLC input should be used.
•
NO FUNCTION
: The PLC input is not used.
•
DEVICE READY
•
GOOD READ
•
NO READ
•
STATUS OF INPUT SENSOR 1
•
STATUS OF INPUT SENSOR 2
•
STATUS OF EXTERNAL INPUT 1
•
STATUS OF EXTERNAL INPUT 2
The parameter is used in conjunction with the CMF400 operating mode to assign prop‐
erties to PLC inputs. As there is no opportunity to use triggers in the CMF400 communi‐
cation mode, instructions can be issued via the input properties.
280
Usage PLC-Output Bit0
parameter specifies how the PLC output should be used.
•
NO FUNCTION
: The PLC output is not used.
•
OBJECT TRIGGER
: A digital trigger signal is sent via the PLC output. To use this func‐
tion, you must set the
OBJECT TRIGGER CONTROL
parameter to the
FIELDBUS INPUT
value.
The
OBJECT TRIGGER CONTROL
parameter is located under
READING CONFIGURATION
->
OBJECT TRIGGER CONTROL
.
•
SET / RESET EXTERNAL OUTPUT 1/2
: External output 1 or 2 is reset. To use this function,
you must set the
EXTERNAL OUTPUT 1
or
EXTERNAL OUTPUT 2
parameter to the
FIELDBUS
INPUT
value. The
EXTERNAL OUTPUT 1/2
parameters can be found under
NETWORK / INTER‐
FACES / IOS
->
DIGITAL OUTPUTS / BEEPER
.
•
DISTANCE CONFIGURATION BIT 0/1
: The
DYNAMIC FOCUS
parameter is controlled via the PLC
output. To use this function, you must set the
DYN. CONF. MODE
parameter to the
FIELDBUS
value.
The parameter is used in conjunction with the CMF400 operating mode to assign prop‐
erties to PLC outputs. As there is no opportunity to use triggers in the CMF400 commu‐
nication mode, instructions can be issued via the output properties.
281
Usage PLC-Output Bit1
parameter specifies how the PLC output should be used.
•
NO FUNCTION
: The PLC output is not used.
•
OBJECT TRIGGER
: A digital trigger signal is sent via the PLC output. To use this func‐
tion, you must set the
OBJECT TRIGGER CONTROL
parameter to the
FIELDBUS INPUT
value.
The
OBJECT TRIGGER CONTROL
parameter is located under
READING CONFIGURATION
->
OBJECT TRIGGER CONTROL
.
•
SET / RESET EXTERNAL OUTPUT 1/2
: External output 1 or 2 is reset. To use this function,
you must set the
EXTERNAL OUTPUT 1
or
EXTERNAL OUTPUT 2
parameter to the
FIELDBUS
INPUT
value. The
EXTERNAL OUTPUT 1/2
parameters can be found under
NETWORK / INTER‐
FACES / IOS
->
DIGITAL OUTPUTS / BEEPER
.
•
DISTANCE CONFIGURATION BIT 0/1
: The
DYNAMIC FOCUS
parameter is controlled via the PLC
output. To use this function, you must set the
DYN. CONF. MODE
parameter to the
FIELDBUS
value.
The parameter is used in conjunction with the CMF400 operating mode to assign prop‐
erties to PLC outputs. As there is no opportunity to use triggers in the CMF400 commu‐
nication mode, instructions can be issued via the output properties.
SOPAS PARAMETER OVERVIEW
96
O N L I N E H E L P | Lector62x
8013778/YPV6/2016-01-14 | SICK