Network / Interface / IOs
Settings for using the CAN bus interface can be made on the
tab. The CDF600 connection module provides SICK reading devices with a CAN inter‐
face that can be used as follows:
•
The CAN interface is used to integrate the device into a SICK network. On a SICK
network, only SICK reading devices are networked via the CAN bus. This type of
device group is used to scan an object from different perspectives and transmit
the reading result to a host. As far as the host is concerned, the device group func‐
tions as an individual device. The master/slave or multiplexer/server operating
modes are available for the SICK network. Both operating modes can be com‐
bined.
•
The reading device can be integrated into an unspecified CAN fieldbus system via
CANopen. The SICK reading device operates as a slave under a CANopen client
(PLC) and can communicate with devices from other manufacturers.
folder in the project tree contains all the parameters for
configuring and activating serial interfaces, fieldbus interfaces, digital inputs and out‐
puts, and beepers.
275
Network Options
group contains parameters for identifying the reading devices on
the network.
276
Restart interval on sending
If the
parameter is activated, the time between the heart‐
beat signals starts running again once the reading results have been output.
277
No Reads
display field shows how many triggers did NOT result in the Good Read
condition being met.
The triggers involved in setting up the sensor are not included in the statistics.
278
Usage PLC-Input Bit0
parameter specifies how the PLC input should be used.
•
NO FUNCTION
: The PLC input is not used.
•
DEVICE READY
•
GOOD READ
•
NO READ
•
STATUS OF INPUT SENSOR 1
•
STATUS OF INPUT SENSOR 2
•
STATUS OF EXTERNAL INPUT 1
•
STATUS OF EXTERNAL INPUT 2
The parameter is used in conjunction with the CMF400 operating mode to assign prop‐
erties to PLC inputs. As there is no opportunity to use triggers in the CMF400 communi‐
cation mode, instructions can be issued via the input properties.
SOPAS PARAMETER OVERVIEW
8013778/YPV6/2016-01-14 | SICK
O N L I N E H E L P | Lector62x