230
Coordinates
group defines the position of the device above the conveying system in
relation to a zero point. Establishing the device position makes it easier to map the
position of an identified object at a later stage.
Looking in the conveying direction, the zero point is usually located on the bottom right-
hand edge of the conveying system.
231
Italic Text
Activating the
parameter enables italic fonts to be read.
This parameter increases the quality and stability of the reading operation when italic
font is used or text is at a slight angle.
232
Length
If the
parameter is set to the
TIMER/TRACKING
condition, the
parameter
can be used to specify how long the digital output should remain activated. The unit
can be selected via the
parameter.
233
Length
Codes with a defined number of characters can be excluded from the reading process
via the parameters in the
group.
Limiting the number of codes to be read reduces the decoding time.
Code length
parameter can be used to restrict the number of characters allowed
within a code.
•
FREE
: Codes of any code length are read.
•
INTERVAL
: The
parameter can be used to define the minimum and maxi‐
mum code length. Codes are only read if their length falls between these two val‐
ues.
•
FIXED
: The
parameter can be used to define several fixed code
lengths. Codes are only read if they feature one of these defined code lengths.
Interval
parameter can be used to define the minimum and maximum code length.
Codes are only read if their length falls between these two values.
By defining a minimum and maximum code length, you can restrict the range of codes
to be read. This can lead to a reduction in the decoding time.
Fixed Codelengths
parameter can be used to define several fixed code lengths. Codes
are only read if they feature one of these defined code lengths.
NOTE
By defining the specific code lengths that are permissible, you can restrict the range of
codes to be read. This can lead to a reduction in the decoding time.
SOPAS PARAMETER OVERVIEW
84
O N L I N E H E L P | Lector62x