184
Function
parameter is used to define the functions of the sensor pushbuttons and
how they should behave.
•
NO FUNCTION
: The function buttons on the sensor are deactivated. This prevents
operational faults from occurring because the buttons have been pushed uninten‐
tionally.
•
TRIGGER AND AIMING LASER
: You can use the pushbuttons on the sensor to initiate
reading without the sensor having to be connected to the PC.
°
The pushbutton on the left opens the reading gate. The reading gate remains
open until you release the pushbutton or until the condition for closing the
reading gate has been met.
°
The pushbutton on the right switches the aiming laser on/off. The aiming
laser switches off automatically after five minutes.
•
MENU (STORE PERMANENTLY)
: The pushbuttons on the sensor act like menu keys and
can be used for configuration. The modified parameter values are permanently
saved in the device. This overwrites the existing values.
•
MENU (STORE TEMPORARILY)
: The pushbuttons on the sensor act like menu keys and
can be used for configuration. The existing values are overwritten just for the time
being. The modified parameter values remain stored in the device until it is
restarted. Given that the old parameter values are restored after the restart, this
setting is suitable for testing parameter changes. This function can also be used if
SOPAS PARAMETER OVERVIEW
70
O N L I N E H E L P | Lector62x
8013778/YPV6/2016-01-14 | SICK
Subject to change without notice