104
Code Quality
The code evaluation settings are made on the
tab. Code evaluations
based on various standards can be used to compare and check reading results from
different sensors.
105
Separate codes depending on position
If the
Separate codes depending on position
parameter is activated, codes of the same
type and with identical content are distinguished from one another according to their
position on the object.
For this to take place, there must be a definable minimum distance (
)
between the identical codes on the object.
106
Label timeout active
If the
parameter is activated, you can define how much time has to
elapse before an identical code may be output again.
107
Code surrounded by patterns
If the
parameter is activated, any lines (e.g., printed con‐
ductors on a PCB) around the code are disregarded during evaluation.
This keeps the reading operation focused on the code elements and reduces the
decoding time.
NOTE
When the function is activated, poor quality codes tend to be ignored.
SOPAS PARAMETER OVERVIEW
46
O N L I N E H E L P | Lector62x
8013778/YPV6/2016-01-14 | SICK
Subject to change without notice