78
Image sequence
displays the captured images one after the other. The images that
were captured last are inserted on the left.
By comparing and evaluating the images that have been captured, it is possible to ana‐
lyze (for example):
•
Whether the trigger has been set correctly and the appropriate section of the read‐
ing field has been captured
•
Whether the codes on moving objects have been captured in focus and whether
the shutter time has been set correctly
•
How often a code was captured per reading gate
NOTE
In order to determine the cause of unsuccessful read operations, it can sometimes be
helpful to analyze the images containing codes that could not be identified (
NO READ
).
Click on the smaller images in the
to display them in the main view.
The file names and storage locations of images are displayed in a tooltip (mouseover).
You can use the
and
buttons to switch between multiple sequences.
The number of images displayed depends on the operating mode and the configura‐
tion:
•
Depending on how the
parameter is configured, either the last
200 individual images (one image per trigger) or sets of 60 images per second are
displayed in individual sequences.
•
During the reading process for testing the configuration (
operating mode),
the system shows the last 30 images captured.
SOPAS PARAMETER OVERVIEW
8013778/YPV6/2016-01-14 | SICK
O N L I N E H E L P | Lector62x
37
Subject to change without notice