355
Beeper
The event that activates the beeper is selected via the
parameter.
•
GOOD READ
: The beeper sounds if the read operation was successful.
•
NO READ
: The beeper sounds if the read operation was unsuccessful.
•
TEACH-IN 1 OK
: The beeper sounds if the
MATCH CODE TEACH-IN 1
has been successfully
taught in.
•
TEACH-IN 1 NOK
: The beeper sounds if the
MATCH CODE TEACH-IN 1
could not be success‐
fully taught in.
•
TEACH-IN 2 OK
: The beeper sounds if the
MATCH CODE TEACH-IN 2
has been successfully
taught in.
•
TEACH-IN 2 NOK
: The beeper sounds if the
MATCH CODE TEACH-IN 2
could not be success‐
fully taught in.
•
MATCH 1 CONDITIONS
: The beeper sounds if the code that has been read corresponds
to the
MATCH 1 CONDITION
match code.
•
MULTICODES1 CONDITION
: The beeper sounds if the number of codes that have been
read corresponds to the number specified by the
MULTICODES1 CONDITION
.
•
TEACH-IN1 CONDITIONS
: The beeper sounds if the code that has been read corre‐
sponds to the
TEACH-IN1 CONDITION
match code.
•
TEACH-IN2 CONDITIONS
: The beeper sounds if the code that has been read corre‐
sponds to the
TEACH-IN2 CONDITION
match code.
356
SVP
The SVP data output can be activated in the
group.
The SVP (SICK Visualization Platform) is a dynamic database used to monitor, analyze,
and evaluate all the information, including camera images and videos that are captured
using automatic SICK data collection systems.
SOPAS PARAMETER OVERVIEW
118
O N L I N E H E L P | Lector62x
8013778/YPV6/2016-01-14 | SICK
Subject to change without notice