Serial AUX Interface
parameter specifies which fieldbus gateway is to be used on
the serial auxiliary interface provided by the CDM4xx connection module.
•
NONE
: No connection module with a fieldbus gateway is connected.
•
PROFIBUS DP
: The CMD4xx connection module is equipped with a Profibus CMF card
that acts as a gateway into the Profibus DP fieldbus system.
•
DEVICENET
: The CMD4xx connection module is equipped with a DeviceNet CMF card
that acts as a gateway into the DeviceNet fieldbus system.
NOTE
To use the interface, you must move the switch on the gateway to the AUX position.
325
Serial host interface
parameter specifies which fieldbus gateway is to be used on
the serial host interface provided by the CDM4xx connection module.
•
NONE
: No connection module with a fieldbus gateway is connected.
•
PROFIBUS DP
: The CMD4xx connection module is equipped with a Profibus CMF card
that acts as a gateway into the Profibus DP fieldbus system.
•
DEVICENET
: The CMD4xx connection module is equipped with a DeviceNet CMF card
that acts as a gateway into the DeviceNet fieldbus system.
•
PROFINET IO
: The device is connected to a CDM425 connection module with a PROFI‐
NET IO gateway, which integrates the reading device into the PROFINET IO Indus‐
trial Ethernet standard.
NOTE
To use the interface, you must move the switch on the gateway to the AUX position.
326
Serial Host
If the
parameter is activated, the results from the serial host interface are
written to the save destination.
327
Server / Client
parameter is used to select what function the sensor should per‐
form within a network.
•
SERVER
: Within a network, the sensor functions as a server.
•
CLIENT
: Within a network, the sensor is subordinate to a server. The server is
defined via the
parameter.
328
Server Address
parameter is used to define the IP address of the server to which
the sensor is subject within a network.
Enable heartbeat
If the
parameter is activated, what happens at regular intervals
(
) is that a signal is output via the interface. In this way, the availabil‐
ity of the sensor can be checked via the interface.