316
Text Color
parameter is used to define the difference in color between the text and
background.
•
BLACK
: Text is darker than the background
•
WHITE
: Text is lighter than the background
•
AUTOMATIC
: Automatic detection
NOTE
To increase the stability of reading it is recommended that the text color is defined.
317
Display Score Values in the Image
If the
Display Score Values in the Image
parameter is activated, the determined score
values are shown in the image.
318
Check SD card
You can check whether the memory card is in working order by pressing the
button.
319
Sensor / Input 1
group contains parameters for adjusting digital input 1.
parameter allows you to choose between a configuration based on
length units and a configuration based on time units.
•
DISTANCE-CONTROLLED
: The configuration is based on distance increments in mm.
These are either generated by the configuration software (SOPAS)/CAN interface
or via a rotary encoder at the digital input.
•
TIME-CONTROLLED
: The configuration is based on times entered in ms.
parameter allows you to choose between edge control and level
control.
•
EDGE
: The digital input responds to the switch between Low (0) and High (1)
according to how the
parameter is configured. Any signal that is permanently
present is ignored.
•
LEVEL
: The digital input responds to a permanently present signal according to how
the
parameter is configured.
parameter is used to select the polarity for the
parameter.
•
NOT INVERTED
: The digital input responds to a rising edge, i.e., to a switch from Low
(0) to High (1), or to a High signal (1) that is permanently present.
•
INVERTED
: The digital input responds to a falling signal edge, i.e., to a switch from
High (1) to Low (0), or to a Low signal (0) that is permanently present.
Depending on how the
parameter is configured, the
param‐
eter specifies the minimum distance in mm or the minimum time in ms for the signal at
the external input. If the value is not achieved, the signal is not detected.
Depending on the application, this value may have to be adapted in line with the read
cycle rates required.
320
Sensor / Input 2
group contains the parameters for adjusting digital input 2.
SOPAS PARAMETER OVERVIEW
106
O N L I N E H E L P | Lector62x
8013778/YPV6/2016-01-14 | SICK
Subject to change without notice