OUT
Live measured value (run mode)
In run mode, the device displays the remission value currently being measured as a
digit.
OUT
Table 6: Remission value indicator
Value
Remission value
0
No remission
3000
Maximum remission at 16 µs response time
9999
Maximum remission at 200 µs response time
7.8
Resetting the device (factory setting)
1.
Press and hold the Mode button for 2 s. The Configuration operating mode is
active.
2.
Use the plus or minus button to select rES.
OUT
3.
Press the Mode button.
4.
Use the plus or minus button to select no or YES.
OUT
OUT
5.
Press the Mode button.
6.
Use the plus or minus button to select End.
7.
Press the Mode button.
Table 7: Factory settings
Setting
Value
Switching mode
Automated
Sensitivity
10
Response time
16 µs
Time delay
Off
Setting display value to
zero
Off
Display setting
Numerical display
energy-saving mode
Off
Display rotation
Off
Input setting
External teach-in
7