Press the Mode button. The preset value flashes.
OUT
6.
Use the plus or minus button to select the required setting.
OUT
16 µs (factory setting)
OUT
200 µs
7.
Press the Mode button.
7.6.2
Setting display value to to zero
This function can be used to change the display of the live measured value and the
switching threshold. If the function is activated, the live measured value is shifted to 0;
the same offset is then subtracted from the switching threshold.
NOTE
The switching outputs and the measured value transmitted to the bus are not affected
by this.
1.
Press and hold the Mode button for 2 s. The Configuration operating mode is
active.
2.
Use the plus or minus button to select Pro.
OUT
3.
Press the Mode button.
4.
Use the plus or minus button to select oFSt.
OUT
5.
Press the Mode button. The preset value flashes.
OUT
6.
Use the plus or minus button to select on or oFF.
OUT
Deactivated (factory setting)
OUT
Active
7.
Press the Mode button.