Reference Manual
Chapter
3
IVC-2D
©
SICK AG • Advanced Industrial Sensors • www.sick.com • All rights reserved
31
Handling the Emulator
Emulator
Click
Browse…
and select a folder containing recorded images.
The Emulator camera type must be of the same type that was
used when recording the images.
Click
OK
.
3.2.2
Basics
To enable the
Emulator
Choose
Emulator
Æ
Enable…
from the IVC Studio menu bar.
The Emulator settings dialog box is opened.
Select which camera type to emulate from the drop-down list.
Enter a numeric camera ID. The ID must be unique within the
Product. Maximum length is 9 digits.
Click
Browse…
and select a folder containing pre-recorded
images. The Emulator camera type must be of the same type
that was used when recording the images.
Click
OK
.
To disable the
Emulator
Choose
Emulator
Æ
Disable
from the IVC Studio menu bar.
The Emulator disappears from the list of Devices.
To enable the
Emulator automa-
tically
Choose
Emulator
Æ
Settings…
from the IVC Studio menu bar.
The Emulator settings dialog box is opened.
Tick
Enable Emulator when launching IVC Studio
and click
OK
.
The Emulator is now automatically enabled when starting IVC
Studio.
To change the
Emulator settings
Choose
Emulator
Æ
Settings…
from the IVC Studio menu bar.
If
Type,
ID,
Number of image banks
or
Number of profile banks
is changed, the Emulator will be restarted.
To access the flash
disk of the Emula-
tor
The flash disk of the Emulator is found on the PC under My
Documents (Documents in Vista) for the current user. The default
path to the Emulator flash is:
My Documents\SICKIVP\SmartCameras\IVC Studio x.x\ Emula-
tor\flash
3.2.3
Using the Grab and the Grab Setup Tools
Each time the Grab tool is executed a new image is read from the image source. The
name of this image file is displayed as a result parameter of the Grab step, and the Grab
Setup parameters saved in the image file are used to update the image banks.
The program thus works as if a Grab Setup step with these settings were executed.
3.2.4
Using Old Images in an Emulated 3D Camera
It is possible to use images that are captured with a version of IVC Studio that does not
support the Emulator. The Grab Setup tool then needs to be executed with the same
settings as were used when capturing the images, since the images do not contain any
setup information.
To use old images
in an emulated 3D
camera
Choose
Emulator
Æ
Settings…
from the IVC Studio menu bar,
select the desired image source folder, and click
OK
.
Configure a Grab Setup step with the same settings that were