Reference Manual
Chapter
4
IVC-2D
©
SICK AG • Advanced Industrial Sensors • www.sick.com • All rights reserved
199
Input/Output
4.12
Input/Output
Read Input
This tool reads the state of an input signal and returns the current status (High or Low).
This enables synchronization of the step program with an external input.
In addition, it is possible to set the tool to wait until the input signal has a specified state,
by setting the
Wait
parameter to
True
and
Wait for
to the state to wait for. Please note
that when running a program that contains such a step, the execution will be halted indefi-
nitely until the signal changes to the selected state. When executing the program step
using Execute Step or Step by Step, the tool will time out after 100 ms.
Input Parameters
01 = Input number
The input signal to read the status of:
Value Signal
Pin
Color
0
Trigger In/In 0
Power connector, pin 1
White
*
1
In 1
Power connector, pin 5
Gray
*
2
In 2
Power connector, pin 6
Pink
*
3
In 3 (IVC-2D)
RS485 connector, pin 8
Red
**
* Color is valid for cable type DOL-1208-
** Color is valid for cable type STL-1208-
02 = Wait
True
Wait until the input signal is high or low, as specified by
Wait for
.
False
Read the status immediately. The input parameter
Wait
for
is ignored.
03 = Wait for
The input signal to wait for.
High
Low
Returned Values
01 = Signal value
Actual status on selected pin.
0 = Low
1 = High
The Emulator does
not emulate this
tool. See section
Handling the
Emulator for more
information.