Chapter
4
Reference Manual
IVC-2D
158
©
SICK AG • Advanced Industrial Sensors • www.sick.com • All rights reserved
Program
Run Flash Program
This tool is used for loading and running a step program that is stored in a program bank in
the flash memory of the device.
Execution of the loaded program starts at the program step specified by the
Start step
parameter.
By setting the parameters
Start load table
index and
Number of elements
, you can specify
which rows of the table stored with the step program that should be loaded with the
program.
The loaded step program will entirely replace the program currently in the working memory.
If you want to continue running the previous program after loading a program from flash,
that program must also be stored in the flash memory, and the loaded program must
contain a 'Run flash program' step that loads the previous program from flash.
Input Parameters
01=Program number
Number of the program bank in which the program
and table to load is saved.
02=Start step
Step number in the loaded program where to start
the execution.
03=Start load table index
Index of the first table row to be loaded from the
table stored with the step program and into the
active table.
04=Number of elements
The number of table rows to be loaded from the
table saved with the step program and into the
active table.
Returned Values
None