NOTE
Assign the functions for the digital inputs in the device using SICK AppStudio.
13.4.8
Wiring digital outputs of the device in the CDM420-0006
Device = InspectorP63x = V2D63xP-xxxxBx
Device
1
CDM420-0006
Load (e.g. PLC)
4
C
5
.
.
.
E
RES/OUT
13
GND
5
Shield
+24 V* (V
S
)
V
S
GND
V
out
Result
A
GND
B
1
2
1
6
1
10
5
11
15
For inductive load:
6
3
1
7
2
6
5
4
8
13
14
17
15
9
10
12
16
11
8
7
Cable
3
5
2
Filter
Figure 28: Wire the digital output in the CDM420-0006 connection module.
1
Device
2
Supply voltage V
S
3
Adapter cable (female connector, M12, 17-pin, A-coded/male connector, D-Sub-HD, 15-pin)
4
Load (e.g. PLC)
5
Output voltage V
out
6
With inductive load: see note
7
Connection module: female connector, D-Sub-HD, 15-pin
8
Device: male connector, M12, 17-pin, A-coded
NOTE
Digital outputs are omitted due to the 15-pin adapter cable.
Not available in CDM420-0006:
•
IN/OUT 5
•
IN/OUT 6
Inductive load
NOTE
Provide an arc-suppression switch at the digital output if inductive load is present.
b
Attach a freewheeling diode directly to the load for this purpose.
Table 23: Assignment of placeholders to the digital outputs
Device
CDM420-0006
Output A
Pin B
Pin C
Signal D
Terminal E
IN/OUT 3
13
12
Result 1
14
ANNEX
13
8019946/1EJ6/2022-02 | SICK
O P E R A T I N G I N S T R U C T I O N S | InspectorP63x Flex C-mount and S-mount
73
Subject to change without notice