The device is in Single deep mode.
3.
Open the
Camera adjustment
window.
4.
How to set the image brightness in Single deep mode:
°
In the
Camera configuration
area, set the
Gain factor
parameter.
°
In the
Camera configuration
area, set the
Shutter time [μm]
parameter.
5.
In the
Fine positioning
area, enable the
Double deep
switch.
✓
The device is in Double deep mode.
6.
Increase the
Gain factor
parameter in double deep mode to a value that offers
sufficient image brightness for positioning marks in double deep racks. To prevent
increased image noise, avoid high values. If high values are necessary, adjust the
shutter time accordingly.
7.
Check the settings in Single deep mode again. If necessary, correct the
Gain factor
in single deep mode.
8.
Activate the
Perform auto gain
parameter to automatically set a suitable image
brightness using the Auto-gain assistant.
✓
The device captures a series of images and automatically sets the
Gain factor
parameter. The Auto-gain assistant and continuous measurement are automati‐
cally deactivated after they are successfully executed.
6.5.15
Setting the communication protocol
Procedure
1.
In SOPASair, open the
Interfaces
window.
2.
In the
Ethernet mode
area, set the communication protocol.
Further topics
•
6.5.16
Image transfer FTP
Procedure
The device can transmit images to an FTP server using file transfer protocol (FTP).
b
Configure the destination address in SOPASair in the
Interfaces
window.
Complementary information
Access details for FTP transfer
•
Name: AppStudio
•
Password: AppStudio
6.5.17
Additional parameters
Other parameters for fine adjustment of the device are available in the
Maintenance
user level. These additional parameters are only relevant to a few applications. A table
listing and explaining all parameters can be found in the appendix,
.
6.5.18
Completing the parameterization
Procedure
1.
To achieve the maximum processing power of the device, image output is disabled
after parameterization has been completed.
✓
A faster positioning process is possible. The system throughput is at its highest.
2.
Save the parameter set on the computer (backup) or to a microSD memory card
(parameter cloning).