Table 3: Available user levels
User levels
Password
Use
Run
No password required
•
Observe the system during operation.
•
Switch continuous measurement on and
off.
•
Activate and deactivate double deep mode.
•
Switch image output on and off.
Operator
No password required
•
Configure additional settings for initial com‐
missioning of the device.
•
Adjust settings during operation (e.g.,
measurement tolerances).
•
Since the device is preconfigured on deliv‐
ery, the parameters available here are usu‐
ally sufficient for operation.
Maintenance
Main
•
User: Maintenance
•
Deep understanding of the application nec‐
essary.
•
All parameters are available.
•
Adjust the device optimally to the circum‐
stances.
•
Detailed configuration of settings during ini‐
tial commissioning.
6.5.4
Setting the user interface language
Procedure
b
Set the user interface language in the
Settings
window.
6.5.5
Loading the device defaults
Procedure
If the device has already been parameterized for another application, then first load the
defaults.
1.
Set the user level to
Maintenance
.
2.
Open the
Advanced setup
window.
3.
Click on the
Restore all default parameters
button.
6.5.6
Setting the positioning mark
Important notes
NOTE
Setting the positioning mark is only relevant for single-deep rack storage.
Procedure
b
In the
Setup
window in SOPASair, set the
Preconfiguration application
parameter.
6.5.7
Performing a fine adjustment
Prerequisites
•
Device is mounted at the same height as the positioning mark.
•
Device is oriented perpendicular to the metal surface or positioning mark.
•
User level
Operator
or
Maintenance
is set.
COMMISSIONING
6
8024534/1DQ8/2022-01-14 | SICK
O P E R A T I N G I N S T R U C T I O N S | InspectorP Rack Fine Positioning
21
Subject to change without notice