Technical Specifications
Operating Instructions
IDM corded & IDM Bluetooth
10
© SICK AG · Germany · All rights reserved · Subject to change without notice
8017159/142O/2019-05-23
1.2
Technical Specifications
1.2.1
IDM Corded Hand-held Scanners
Type
IDM120
IDM140
IDM160
IDM240
IDM260
Field of
application
General Purpose General Purpose
Industrial
General Purpose
Industrial
Enclosure
rating
IP 41
IP 41
IP 65
IP 41
IP 65
Supported
code types
1D, Stacked
1D, Stacked, 2D
1D, Stacked, 2D
Code
resolution
≥0.102 mm
1)
≥0.076 mm
1)
≥0.0
7 mm
1)
, ≥0.13 mm
2)
Reading
distance
(at code
resolution)
0 mm ... 400 mm
(0.102 mm)
1)
20 mm ... 850 mm
(0.5 mm)
1)
20 mm ... 850 mm
(0.5 mm)
1)
SR model:
30 mm ... 400 mm (0.25 mm)
2)
Interfaces
USB (Keyboard Wedge & Com Port Emulation), RS-232,
(Ethernet TCP/IP, PROFINET, PROFIBUS, DeviceNet)
Optical
indicators
1 LED
(good read)
2 LEDs (operational status, good read)
Vibration
No
No
Yes
No
Yes
Acoustic
indicators
Beeper, disengageable
Operating
Voltage
5 V DC (+/- 5%)
Current
consumption
(Operating)
Typical
170 mA
Typical 180 mA
180 mA
(Vibrator disabled)
230 mA
(Vibrator enable)
Typical 395 mA
Max. 395 mA
(Vibrator disabled)
Max. 420 mA
(Vibrator enable)
Current
consumption
(Standby)
Typical 75 mA
Typical 80 mA
Typical 80 mA
Typical 220 mA
Max. 220 mA
Light source
LED: visible red light (630 nm)
Laser aimer
No
Yes (Laser Class 1)
Ambient
operating
temperature
0 °C ... 50 °C
-10°C … 50°C
-20 °C ... 50 °C
-10 °C ... 50 °C
-20 °C ... 50 °C
Storage
temperature
-20 °C ... 60 °C
-40 °C ... 70 °C
-30 °C ... 70 °C
-40 °C ... 70 °C
-40 °C ... 70 °C
1)
Valid for Code 39,
2)
Valid for Data Matrix
1
Depending on scanner version (PDF version is necessary).
2
Depending on scanner version, option of low performance DPM Code reading can be enabled via Plug-in
3
Optional via external SICK connection modules.