Operating Instructions
Chapter
3
ICR890
Product description
8011325/0000/2006-10-24
©
SICK AG · Division Auto Ident · Germany · All rights reserved
39
3.4.10
Output format
The reading result (decoded codes) is displayed via definable data interfaces. Two different
output formats (telegrams) can be defined for this task.
Two output formats can be configured using the SOPAS-ET Configuration Software:
P
ROJECT
T
REE
, ICR890, P
ARAMETER
, D
ATA
PROCESSING
, O
UTPUT
F
ORMAT
3.4.11
Network
Although all important interfaces for displaying the reading results are available at the
ICR890 System, the system is operated via the MSC800 Controller as standard. The
MSC800 assumes system coordination for multi-side readings. The ICR890 System and the
MSC800 can be networked via the CAN bus.
The network parameters can be configured using the SOPAS-ET Configuration Software:
P
ROJECT
T
REE
, ICR890, P
ARAMETER
, N
ETWORK
A
RCHITECTURE
, register tabs N
ETWORK
O
PTIONS
and
M
ASTER
/S
LAVE
3.4.12
Data interfaces
Numerous data interfaces are available at the ICR890 System.
The data interfaces can be configured using the SOPAS-ET Configuration Software:
P
ROJECT
T
REE
, ICR890, P
ARAMETER
, I
NTERFACES
, S
ERIAL
P
ROJECT
T
REE
, ICR890, P
ARAMETER
, I
NTERFACES
, E
THERNET
P
ROJECT
T
REE
, ICR890, P
ARAMETER
, I
NTERFACES
, GB
IT
E
THERNET
P
ROJECT
T
REE
, ICR890, P
ARAMETER
, I
NTERFACES
, CAN
Data interface
Connection
Function
Serial host
interface
HOST
Preparation of the reading result for further processing by
the host processor
Serial host
interface
AUX
Reading diagnosis
Ethernet
HOST ETHERNET
Preparation of the reading result for further processing by
the host processor
GBit Ethernet:
GBIT ETHERNET
Preparation of the image data of the current reading for
further processing
CAN bus
CAN 1 (Out/In),
CAN 2 (Out/In)
Networking one or several systems with the MSC800
Tab. 3-4: Data interface function